ENTER/EXIT PROGRAMMING MODE
102
MAGELLAN™ 1500I
RS-232 ACK NAK Timeout Value
This item specifies the time the scanner will wait for an ACK character from the host follow
ing a label transmission.
0 = Infinite timeout
•1 75
= Timeout in 200millisecond increments
To set the ACK NAK Timeout Value:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode below,
Set RS-232 ACK NAK Timeout Value. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre
sent the desired timeout. A setting of 0 specifies an infinite timeout. The remaining
select
able range is 175, which is the timeout in 200millisecond increments. Pad all
single digit numbers with a leading zero to yield a twodigit entry (0075).
Examples:
00 = Infinite timeout
01 = 200ms
05 = 1,000ms (1 second)
40 = 8,000ms (8 seconds)
75 = 15,000ms (15 seconds)
The scanner will automatically exit Programming Mode when the appropriate amount of
digits have been scanned.
0606(CR)
Set RS-232 ACK NAK Timeout Value
Default setting for this feature is:
01 - 200ms
DEFAULT