OTHER UPC/EAN OPTIONS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
161
UPC/EAN Stitch Exact Label Halves
This setting enables the stitching of exact UPCA/EAN13 label halves with no overlapping
characters.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
bar
code.
054100(CR)
UPC/EAN Stitch Exact Label Halves = Disable
054101(CR)
UPC/EAN Stitch Exact Label Halves = Enable