UPC/EAN Minimum Segment Length
This feature specifies the minimum number of characters needed in a UPC/EAN segment in
order to be accepted for decoding.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode for the desired setting below. You’ll need to cover any unused bar‐
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
bar
code.
UPC/EAN Minimum Segment Length = 5 Characters
UPC/EAN Minimum Segment Length = 6 Characters
UPC/EAN Minimum Segment Length = 7 Characters
UPC/EAN Minimum Segment Length = 8 Characters
UPC/EAN Minimum Segment Length = 9 Characters