CODE 128 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
215
Code 128 Length 1
If Code 128 Length Control is set to FixedLength decoding, this feature specifies Code 128
first fixed length. If Code 128 Length Control is set to VariableLength decoding, this feature
specifies the minmum label length.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Code 128 Length 1 on page 215 below. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the
barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre
sent the desired label length. The selectable range for this option is 01 to 80. Pad all
single digit
numbers with a leading zero to yield a twodigit entry (0180).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar
code.
04B8(CR)
Set Code 128 Length 1
Default setting for this feature = 01