ENTER/EXIT PROGRAMMING MODE
216
MAGELLAN™ 1500I
Code 128 Length 2
If Code 128 Length Control is set to Fixed‐Length decoding, this feature specifies Code 128
second fixed length. If Code 128 Length Control is set to Variable‐Length decoding, this fea‐
ture specifies the maximum label length.
NOTE
When in Fixed Length mode, if Length 2 is set to the value of 00
(zero), then only Length 1 will apply.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Code 128 Length 2 on page 216 below. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the
barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre‐
sent the desired label length. The selectable range for this option is 01 to 80. Pad all
single digit
numbers with a leading zero to yield a two‐digit entry (01‐80).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar
code.
Set Code 128 Length 2
Default setting for this feature = 50 (length = 80)
DEFAULT