ENTER/EXIT PROGRAMMING MODE
230
MAGELLAN™ 1500I
Codabar Check Character Calculation
Enables/disables calculation and verification of an optional Codabar check character.
NOTE
If check character calculation is disabled, the risk is increased
that a misread can occur. When disabled, any check characters in
a barcode are treated as data characters.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar
code.
007100(CR)
Codabar Check Character Calculation = Disable
007101(CR)
Codabar Check Character Calculation = Enable
DEFAULT

Table of Contents