CODE 93 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
241
Code 93 Length 2
If Code 93 Length Control is set to FixedLength decoding, this feature specifies Code 93
second fixed length. If Code 93 Length Control is set to VariableLength decoding, this fea
ture specifies the maximum label length.
NOTE
When in Fixed Length mode, if Fixed Length 2 is set to the value
of 00 (zero), then only Length 1 will apply.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Code 93 Length 2 on page 241 below. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the
barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre
sent the desired label length. The selectable range for this option is 00 (meaning
ignor
e this length), or 01 to 50. Pad all single digit numbers with a leading zero to yield
a twodigit entry (0150).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar
code.
0686(CR)
Set Code 93 Length 2
Default setting for this feature = 32 (length = 50)
DEFAULT