ENTER/EXIT PROGRAMMING MODE
272
MAGELLAN™ 1500I
QR Code Length Control
Fixed Length Decoding:
When fixed length decoding is enabled, the scanner will decode a
barcode if the label length matches one of the configurable fixed lengths.
Variable Length Decoding:
When variable length decoding is enabled, the scanner will
decode a ar code if the label length falls in the range of the configurable minimum and max
imum length.
Configuring Fixed Length Decoding:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the Fixed Length Decoding barcode.
3. Scan the Enter/Exit Programming Mode barcode at the top of the page.
4. Set Length 1 to the first fixed length using the
QR Code Length 1, Length 2 Program-
ming Instructions on page 273 that follow this page.
5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length)
using the
QR Code Length 1, Length 2 Programming Instructions on page 273.
Configuring Variable Length Decoding:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the Variable Length Decoding barcode.
3. Scan the Enter/Exit Programming Mode barcode at the top of the page.
4. Set Length 1 to the minimum length using the
QR Code Length 1, Length 2 Program-
ming Instructions on page 273 that follow this page.
5. Set Length 2 to the maximum length using the
QR Code Length 1, Length 2 Program-
ming Instructions on page 273
.
03D900(CR)
QR Code Length Control = Variable Length
03D901(CR)
QR Code Length Control = Fixed Length
DEFAULT

Table of Contents