ENTER/EXIT PROGRAMMING MODE
280
MAGELLAN™ 1500I
Aztec Length Control
Fixed Length Decoding:
When fixed length decoding is enabled, the scanner will decode a
barcode if the label length matches one of the configurable fixed lengths.
Variable Length Decoding:
When variable length decoding is enabled, the scanner will
decode a ar code if the label length falls in the range of the configurable minimum and max‐
imum length.
Configuring Fixed Length Decoding:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the Fixed Length Decoding barcode.
3. Scan the Enter/Exit Programming Mode barcode at the top of the page.
4. Set Length 1 to the first fixed length using the
Aztec Length 1, Length 2 Programming
Instructions on page 281 that follow this page.
5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length)
using the
Aztec Length 1, Length 2 Programming Instructions on page 281.
Configuring Variable Length Decoding:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the Variable Length Decoding barcode.
3. Scan the Enter/Exit Programming Mode barcode at the top of the page.
4. Set Length 1 to the minimum length using the
Aztec Length 1, Length 2 Programming
Instructions on page 281 that follow this page.
5. Set Length 2 to the maximum length using the
Aztec Length 1, Length 2 Programming
Instructions on page 281
.
Aztec Length Control = Variable Length
Aztec Length Control = Fixed Length
DEFAULT