EasyManua.ls Logo

Datalogic Magellan 1500i - Illumination During Disable Mode

Datalogic Magellan 1500i
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
51
Illumination During Disable Mode
This feature allows illumination to be turned off when the scanner is in “disable” mode. It
determines if the imager illumination is controlled by host interface enable/disable com
mands.
Disable = Illumination is not controlled by host enable/disable commands, illumination
stays on when disabled.
Enable
= Illumination is controlled by host enable/disable commands, illumination is on
when enabled and off when disabled.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
bar
code.
063A00(CR)
Illumination During Disable Mode = Disable
063A01(CR)
Illumination During Disable Mode = Enable
DEFAULT