IMAGING FEATURES ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
71
Number of Imager Frames
This feature specifies the number of consecutive frames captured while using imager regis‐
ter values to toggle between Near Field and Far Field performance. This can be used when a
gr
eater depth of field is needed.
• Byte0 = num frames using Set A
Byte1 = num frames using Set B
•Byte0 = zero
Byte1 = zero: Toggling is disabled. Reg values for current mode used.
•Byte0 = zero
Byte1 = nonzero: Reg values for toggle Set B always used.
• Byte0 = nonzero
Byte1 = zero: Reg values for toggle Set A always used.
• Byte0 = nonzero
Byte1 = nonzero: Reg values toggle between Set A and Set B.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode
Set Number of Frames below. You’ll need to cover any unused bar‐
codes on this and the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C.
4. Scan the Enter/Exit Programming Mode barcode at the top of the page to exit Pro‐
gramming Mode.
Set Number of Frames
Default setting for this feature is: 0 (Near Field)
DEFAULT