ENTER/EXIT PROGRAMMING MODE
78
MAGELLAN™ 1500I
INTERFACE FEATURES
Maximum Host-Transmitted Message Length
Specifies the maximum number of data characters allowed in messages transmitted to the
host.
To set the Maximum Host‐T
ransmitted Message Length:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Maximum Host-Transmitted Message Length on page 78 below.
You’ll need to cover any unused barcodes on this and the facing page to ensure that
the
scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad on page 305 that repre‐
sent the desired maximum host‐t
ransmitted message length. The selectable range is
0‐249 data characters. (Labels that are longer than this length are not read.) Pad all
single and double digit numbers with leading zeroes to yield a three‐digit entry (000‐
249).
NOTE
If this configuration item is set to 0 (000), there is no general length
limit
imposed on data being transmitted to the host.
4. The scanner will automatically exit Programming Mode when the appropriate
amount of digits have been scanned.
Set Maximum Host-Transmitted Message Length
Default setting for this feature is:
000 - No general limit imposed
DEFAULT