UPC-E Check Character Transmission Enter/Exit Programming Mode
Product Reference Guide
123
UPC-E Check Character Transmission
Enables/disables transmission of a UPC-E check character.
NOTE
This item is ignored when the advanced feature, Full Label Edit, is
en
abled.
To set this feature:
1. Scan the Enter/Exit Progr
amming Mode bar code.
2. Scan either the enable or disable bar code below. You’
ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by
scanning the Enter/Exit Pro-
gramming Mode bar code.
004000(CR)
UPC-E Check Character Transmission = Disable
004001(CR)
UPC-E Check Character Transmission = Enable