Enter/Exit Programming Mode Code 32 Start Stop Character Transmission
196 Magellan™ 3450VSi
Code 32 Start Stop Character Transmission
Enables/ disables transmission of start and stop characters for Code 32.
NOTE
This item is ignored when the advanced feature, Full Label Edit, is
en
abled.
To set this feature:
1. Scan the ENTER/EXIT Prog
ramming Mode bar code.
2. Scan either the enable or disable bar code below. You’
ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence
by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
DEFAULT
00F600(CR)
Code 32 Start Stop Character Transmission = Disable
00F601(CR)
Code 32 Start Stop Character Transmission = Enable