Code 128 Length 2 Enter/Exit Programming Mode
Product Reference Guide
205
Code 128 Length 2
If Code 128 Length Control is set to Fixed-Length decoding, this feature speci-
fies Code 128 second fixed length. I
f Code 128 Length Control is set to Vari-
able-Length decoding, this feature specifies the maximum label length.
NOTE
When in Fixed Length mode, if Length 2 is set t
o the value of 00
(zero), then only Length 1 will apply.
To set this feature:
1. Scan the ENTER/EXIT Prog
ramming Mode bar code.
2. Scan the bar code, Set Code 128 Length 2 on page 205 below. You’ll need
to cover any unused bar codes on this and the facing pag
e to ensure that
the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Alpha-Numeric Keypad in Appendix C
that represent the desired l
abel length. The selectable range for this
option is 01 to 80. Pad all single digit numbers with a leading zero to yield
a two-digit entry (01-80).
4. Complete the programming sequence
by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
Set Code 128 Length 2
DEFAULT
Default setting for this feature = 50 (length = 80)