Object Sense Control Enter/Exit Programming Mode
Product Reference Guide 21
Object Sense Control
This feature determines whether the main illumination is controlled by the
Object Sensing system, or alternatively, stays continuously on.
Enable
= Illumination is controlled by using Object Sense
Disable =
Normal illumination is used but it goes off during sleep mode /
disable mode
To set this feature:
1. Scan the Enter/Exit Progr
amming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any
unused bar codes on this and
the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by
scanning the Enter/Exit Pro-
gramming Mode bar code.
DEFAULT
02FD01(CR)04EA40(CR)04CD0B(CR)
Object Sense Control = Enable
02FD00(CR)04EA8B(CR)
Object Sense Control =Disable