Enter/Exit Programming Mode Good Read Beep Length
30 Magellan™ 3450VSi
Good Read Beep Length
Specifies the duration of a good read beep.
To set this feature:
1. Scan the Enter/Exit Programming
Mode bar code.
2. Scan the bar code, Set Good Read Beep Length on page 30. You’ll need to
cover any unused bar codes on this and the f
acing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Alpha-Numeric Keypad in Appendix C
that represent the desired good read beep length setting. The selectable
ra
nge is 1-255, which is the timeout in 10-millisecond increments. Times
have a tolerance of +/-25%. Pad all single and double digit numbers with
leading zeroes to yield a three-digit entry (001-255).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits
have been scanned
Set Good Read Beep Length
DEFAULT
Default setting for this feature is:
008 - 80ms
.