EasyManua.ls Logo

Datalogic Magellan 3450VSi - Cell Mode Percent

Datalogic Magellan 3450VSi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Imaging Features Enter/Exit Programming Mode
Product Reference Guide 41
Cell Mode Percent
Specifies the rate of frames dedicated to reading cell phones. Cell reading fea-
ture must be enabled for this to
be active. The setting reflects a variable setting
(or percentage) of frames dedicated to cell reading
NOTE
DEFAULT
047100(CR)
Cell Mode Percent = 2.5% (Very Low)
047101\r
Cell Mode Percent = 5% (Low)
047102\r
Cell Mode Percent = 10% (Medium)
047103\r
Cell Mode Percent = 20% (Medium High)
047104\r
Cell Mode Percent = 50% (High)
As the percentage is increased, object sense (if enabled) will
become less responsive. Anything above 10% will have a negative
impact on scanning performance.

Table of Contents