RS-232 Interface Features Enter/Exit Programming Mode
Product Reference Guide
65
RS-232 Hardware Control
Enables/disables use of the RS-232 CTS signal for flow control and/or scan
control.
Options are:
• Disable — The scanner transmits to the
host regardless of any activity on
the CTS line.
• Enable CTS Flow Control — The CTS signal co
ntrols transmission of data to
the host.
• Enable CTS Scan Control — The CTS line must be active for scanner to read
a
nd transmit data. While the CTS line is inactive, scanner remains in a
host- disabled state; following a successful label transmission, the CTS
signal must transition to inactive and then to active to enable scanning for
the next label.
• Enable Magellan SL CTS Scan Control —
Follows the same hardware proto-
col as older Magellan SL scanners.
DEFAULT
RS-232 Hardware Control = Disable
RS-232 Hardware Control = Enable CTS Flow Control
RS-232 Parity = Enable CTS Scan Control