Enter/Exit Programming Mode Single Cable RS-232 Use STX
82 Magellan™ 3450VSi
Set Single Cable RS-232 STX Character
This feature selects the STX character.
To specify the STX Character:
1. Scan the Enter/Exit Programming
Mode bar code.
2. Scan the bar code, Set Si
ngle Cable RS-232 STX Character below. You’ll
need to cover any unused bar codes on this and the facing page to ensure
the scanner reads only the bar code you intend to scan.
3. Scan the appropriate characters/digits from the Alpha-Numeric Keypad in
Appendix C that represent the decimal desi
gnation for the desired charac-
ter. A table containing the ASCII Cha
racter Set and their corresponding
decimal values is available in the inside back cover of this manual. ASCII
parameters must be input by scanning decimal digits for each character.
Pad all numbers with leading zeroes to yield a three-digit entry (001-127).
Thus, to set a single character value of A, bar codes containing the digits
‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any
decimal value from 001 to 127.
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits
have been scanned.
Set Single Cable RS-232 STX Character
DEFAULT
Default setting for this feature is:
053 - S