ENTER/EXIT PROGRAMMING MODE
134
MAGELLAN™ 900I
UPC/EAN Stitch Exact Label Halves
This setting enables the stitching of exact UPC-A/EAN-13 label halves with no overlapping
characters.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You’ll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
barcode.
UPC/EAN Stitch Exact Label Halves = Disable
UPC/EAN Stitch Exact Label Halves = Enable
DEFAULT
054100(CR)
054101(CR)