ENTER/EXIT PROGRAMMING MODE
150
MAGELLAN™ 900I
UPC/EAN Composites
Enables/Disables Composites for the UPC/EAN families of labels.
The value is a bit field where the bits mean the following:
• A setting of 0 (zero) disables this feature.
• Bit0 - if set enabled Composites for UPCE, If clear disables Composites for UPCE
• Bit1 - if set enabled Composites for UPCA, If clear disables Composites for UPCA
• Bit2 - if set enabled Composites for EAN8, If clear disables Composites for EAN8
• Bit3 - if set enabled Composites for EAN13, If clear disables Composites for EAN13:
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode below. You’ll need to cover any unused barcodes on this and the fac-
ing page to ensure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad on page 324 that repre-
sent the desired number. The selectable range is 0-15 resets. Pad all single and double
digit numbers with leading zeroes to yield a two-digit entry (00-15).
4. Complete the programming sequence by scanning the Enter/Exit Programming Mode
barcode.
SetUPC/EAN Composites
Default setting for this feature is:
00 - Disabled
02FE(CR)
DEFAULT