DATABAR LIMITED ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
159
DataBar Limited 2D Component Enable
This feature controls if a 2D label component be decoded when a Databar Limited base
label is decoded.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You’ll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
Databar Limited 2D Component = Disable
Databar Limited 2D Component = Enable
DEFAULT
035800(CR)
035801(CR)