INTERLEAVED 2 OF 5 (I 2 OF 5) ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
191
I 2 of 5 Check Character Calculation
Enables/disables calculation and verification of an optional Interleaved 2 of 5 check charac-
ter.
1. To set this feature:
2. Scan the Enter/Exit Programming Mode barcode at the top of the page.
3. Scan either the enable or disable barcode below. You’ll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
NOTE
If check character calculation is disabled, the risk is increased
that a misread can occur. When disabled, any check characters in
a barcode are treated as data characters.
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation = Enable
DEFAULT
007000(CR)
007001(CR)