ENTER/EXIT PROGRAMMING MODE
206
MAGELLAN™ 900I
Codabar Length 2
If Codabar Length Control is set to Fixed-Length decoding, this feature specifies Codabar
second fixed length. If Codabar Length Control is set to Variable-Length decoding, this fea-
ture specifies the maximum label length.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Codabar Length 2 on page 206 below. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre-
sent the desired label length. The selectable range for this option is 00 (meaning
ignore this length), or 03 to 50. Pad all single digit numbers with a leading zero to yield
a two-digit entry (03-50).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
NOTE
When in Fixed Length mode, if Length 2 is set to the value of 00
(zero), then only Length 1 will apply.
Set Codabar Length 2
Default setting for this feature = 32 (length = 50)
0239(CR)
DEFAULT