ENTER/EXIT PROGRAMMING MODE
216
MAGELLAN™ 900I
MSI Check Character Transmission
Enables/disables transmission of optional MSI check characters.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You’ll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
NOTE
This feature applies only when
MSI Check Character Calculation
on page 214
is enabled. This item is ignored when the advanced
feature, Full Label Edit, is enabled.
MSI Check Character Transmission = Disable
MSI Check Character Transmission = Enable
00BE00(CR)
00BE01(CR)
DEFAULT

Table of Contents