ENTER/EXIT PROGRAMMING MODE
260
MAGELLAN™ 900I
Micro PDF 417 Length 1, Length 2 Programming Instructions
If Micro PDF 417 Length Control is set to Fixed-Length decoding, this feature specifies Micro
PDF 417 first fixed length. If Micro PDF 417 Length Control is set to Variable-Length decod-
ing, this feature specifies the minimum label length.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Micro PDF 417 Length 1 on page 260 or Set Micro PDF 417 Length
2 on page 260
below. You’ll need to cover any unused barcodes on this and the facing
page to ensure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre-
sent the desired label length. The selectable range for this option is 0001 to 0366. Pad
all numbers with leading zeros to yield a four-digit entry (0001-0366).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
NOTE
This tag is only valid for units with a model ID that supports
PDF.
Length 1 is the minimum label length if in variable length
mode, or the first fixed length if in fixed length mode. Length
2 is the maximum label length if in variable length mode, or
the second fixed length if in fixed length mode. Length
includes the barcode's data characters only. Any value >
0366 will be considered to be 0366.
Set Micro PDF 417 Length 1
Default setting for this feature = 0001
Set Micro PDF 417 Length 2
Default setting for this feature = 016E (length = 366)