ENTER/EXIT PROGRAMMING MODE
264
MAGELLAN™ 900I
QR Code Length 1, Length 2 Programming Instructions
If QR Code Length Control is set to Fixed-Length decoding, this feature specifies QR Code
first fixed length. If QR Code Length Control is set to Variable-Length decoding, this feature
specifies the minimum label length.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set QR Code Length 1 on page 264 or Set QR Code Length 2 on page
264
below. You’ll need to cover any unused barcodes on this and the facing page to
ensure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C that repre-
sent the desired label length. The selectable range for this option is 0001 to 2710. Pad
all numbers with leading zeros to yield a four-digit entry (001-02710).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
NOTE
Length 1 is the minimum label length if in variable length
mode, or the first fixed length if in fixed length mode. Length
2 is the maximum label length if in variable length mode, or
the second fixed length if in fixed length mode. Length
includes the barcode's data characters only. Any value >
2710 will be considered to be 2710.
Set QR Code Length 1
Default setting for this feature = 0001
Set QR Code Length 2
Default setting for this feature = 0A96 (length = 2710)