ENTER/EXIT PROGRAMMING MODE
38
MAGELLAN™ 900I
Green Spot Duration Time
This feature specifies the time that the Green Spot is active during handheld mode.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
barcode.
150200(CR)
Green Spot Duration = Disabled
150205(CR)
Green Spot Duration = 50 mS
15020A(CR)
Green Spot Duration = 100 mS
15021E(CR)
Green Spot Duration = 300 mS
150264(CR)
Green Spot Duration = 1 second
1502FA(CR)
Green Spot Duration = 2.5 sec