Enter/Exit Programming Mode
Product Reference Guide
119
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode bar
code.
DEFAULT
063A00(CR)
Illumination Control = Disable
063A01(CR)
Illumination Control = Enable
2D Contrast Improvement
This feature enables / disables the scanners ability to enhance the image contrast for scanned 2D
symbologies.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes
on this
and the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
DEFAULT
040F00(CR)
2D Contrast Improvement = Disable
040F01(CR)
2D Contrast Improvement = Enable