Enter/Exit Programming Mode
Product Reference Guide
125
Good Read Beep Length
Specifies the duration of a good read beep.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set Good Read Beep Length. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired
good read beep length setting. The selectable range is 1-255, which is the
timeout in 10-
millisecond increments. Times have a tolerance of +/-25%. Pad all single and double digit
numbers with leading zeroes to yield a three-digit entry (001-255).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming M
ode when the appropriate amount of
digits have been scanned
0016(CR)
Set Good Read Beep Length
DEFAULT
Default setting for this feature is:
008 - 80ms
.