Scale Enforced Zero Return
This feature sets the mode of enforcing the scale re-zeroing operation:
•Disable
Non-zero for more than 4 minutes OR below zero
Non-zero for more than 4 minutes OR below zero OR no zero between weights
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes
on this
and the facing page to ensure that the scanner reads only the bar code you intend
to scan. The strategy is to select the lowest possible filter level needed that allows normal
scale operation.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
040800(CR)
Scale Enforced Zero Return = Disable
040801(CR)
Scale Enforced Zero Return = Non Zero for More Than 4
minutes OR Below Zero
040802(CR)
Scale Enforced Zero Return = Non Zero for More Than 4
minutes OR Below Zero OR No Zero Between Weights
040803(CR)
Scale Enforced Zero Return = Non Zero for 4 minutes
DEFAULT