Enter/Exit Programming Mode
Product Reference Guide
153
EAS Beep Duration
Sets the duration of the EAS successful deactivation beep, specified in 10ms increments.
The beep only occurs if EAS mode is not disabled.
To set the EAS Beep Duration:
1. Scan the Enter/Exit Programmin
g Mode bar code.
2. Scan the bar code, Set EAS Beep Duration below. You’ll need to cover any unused
bar codes on this and the facing page to ensure
that the scanner reads only the bar code
you intend to scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
EAS Beep Duration. The selectable range is 0-255, which is the timeout in 10-mi
lli-
second increments. Pad all single and double digit numbers with l
eading zeroes to
yield a three-digit entry (000-255).
Examples:
000 = EAS beep disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. Complete the programming sequence by scan
ning the nter/Exit Programming Mode
bar code.
Set EAS Beep Duration
DEFAULT
Default setting for this feature is:
008 - 80ms