Enter/Exit Programming Mode
Product Reference Guide
161
ERI Timeout
Specifies the amount of time that an ERI signal is held in its active state for a good read.
To set the ERI Timeout:
1. Scan the Enter/Exit Programmin
g Mode bar code.
2. Scan the bar code, Set ERI Timeout below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the s
canner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
duration. The selectable range i
s 1-255, which is the duration in 10-millisecond incre-
ments. Pad all single and double digit numbers
with leading zeros to yield a three-digit
entry (001-255).
Examples:
000 = ERI timeout disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
NOTE
A setting of 0 (000) disables this feature.
4. The scanner will automatically exit Programming Mode when the appropriate amount
of digits have been scanned.
00FA(CR)
Set ERI Timeout
DEFAULT
Default setting for this feature is:
002 -20ms