Enter/Exit Programming Mode
Product Reference Guide
161
ERI Timeout
Specifies the amount of time that an ERI signal is held in its active state for a good read.
To set the ERI Timeout:
1. Scan the Enter/Exit Programmin
g Mode bar code.
2. Scan the bar code, Set ERI Timeout below. You’ll need to cover any unused bar
codes on this and the facing page to ensure that the s
canner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
duration. The selectable range i
s 1-255, which is the duration in 10-millisecond incre-
ments. Pad all single and double digit numbers
with leading zeros to yield a three-digit
entry (001-255).
Examples:
000 = ERI timeout disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
NOTE
A setting of 0 (000) disables this feature.
4. The scanner will automatically exit Programming Mode when the appropriate amount
of digits have been scanned.
Set ERI Timeout
DEFAULT
Default setting for this feature is:
002 -20ms