EasyManua.ls Logo

Datalogic Magellan 9800i - IBM Features; IBM Interface Options

Datalogic Magellan 9800i
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
170
Magellan™ 9800i Scanner
IBM Features
IBM Interface Options
IBM interfaces offer specific control over interaction with certain devices.
NOTE
The USB OEM interface provides its own set of options. Refer to
the feature, USB OEM Interface Options, in this section.
Options for this feature are as follows:
FULL host interface support — Accepts scanner and scale configuration host commands.
Ignore host interface configuration of scanner and
scale — Ignores all scanner and scale
configuration host commands.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes
on this and
the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
DEFAULT
055000(CR)
IBM Interface Option = Full Host Interface Support
055006(CR)
IBM Interface Option = Ignore Host I/F Config of Scanner &
Scale

Table of Contents

Other manuals for Datalogic Magellan 9800i

Related product manuals