46XX Number of Host Resets
This setting specifies the number of consecutive resets before entering label Programming Mode
to allow scanner configuration.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code,
Set 46XX Number of Host Resets below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner reads only the bar
code y
ou intend to scan.
3. Scan the appropriate digits from the
Keypad in Appendix C that represent the desired
number of resets. The selectable range is 01-15 dat
a characters. Pad all single digit num-
bers with a leading zero to yield a two-digit entry (01-15).
4. Scan the Enter/Exit Programming Mode bar code to exit Programming Mode.
0330(CR)
Set 46XX Number of Host Resets
DEFAULT
Default setting for this feature is: 06 (six resets)