Enter/Exit Programming Mode
196
Magellan™ 9800i Scanner
RS-232 ACK NAK Timeout Value
This item specifies the time the scanner will wait for an ACK character from the host following
a label transmission.
0 = Infinite timeout
1 - 75 = Timeout in 200-millisecond increments
To set the ACK NAK Timeout Value:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code below,
Set RS-232 ACK NAK Timeout Value. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner reads only the bar
code y
ou intend to scan.
3. Scan the appropriate digits from the
Keypad in Appendix C that represent the desired
timeout. A setting of 0 specifies an infinite timeout. The
remaining selectable range is 1-
75, which is the timeout in 200-millisecond increments. Pad all single digit numbers with
a leading zero to yield a two-digit entry (00-75).
Examples:
00 = Infinite timeout
01 = 200ms
05 = 1,000ms (1 second)
40 = 8,000ms (8 seconds)
75 = 15,000ms (15 seconds)
The scanner will automatically exit Programming Mode when
the appropriate amount of digits
have been scanned.
0606(CR)
Set RS-232 ACK NAK Timeout Value
DEFAULT
Default setting for this feature is:
01 - 200ms