Enter/Exit Programming Mode
202
Magellan™ 9800i Scanner
Single Cable RS-232 RTS CTS Selection
Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner
and can be continuously held high/low, or can be asserted during label transmission.
The scanner
looks at CTS, as the configuration values state, to determine when to send label data.
Choices are:
Option 0 = RTS is held in low state and CTS is ignored
Option 1 = RTS is held in high state and CTS is ignored
Option 2 = Assert RTS and wait for CTS to be asserted
Option 3 = Assert RTS and ignore CTS
Option 4 = RTS held low, wait for CTS to be asserted
Option 5 = RTS held high, wait for CTS to be asserted
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan a bar code below or on the following pages representing the desired option. You’ll
need to co
ver any unused bar codes, as well as facing pages to ensure that the scanner reads
only the bar code you intend to scan.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
047B00(CR)
Single Cable RS-232 RTS CTS Selection = Option 0
047B01(CR)
Single Cable RS-232 RTS CTS Selection = Option 1
047B02(CR)
Single Cable RS-232 RTS CTS Selection = Option 2
047B03(CR)
Single Cable RS-232 RTS CTS Selection = Option 3