Enter/Exit Programming Mode
Product Reference Guide
345
Code 93 Length 2
If Code 93 Length Control is set to Fixed-Length decoding, this feature specifies Code 93
second fixed length. If Code 93 Length Control is set to Variable-Length decoding, this feature
specifies the maximum label length.
NOTE
When in Fixed Length mode, if Fixed Length 2 is set to the value of 00
(zero), then only Length 1 will apply.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the barcode, Set Code 93 Length 2 below. You’ll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads only the barcode you
intend to scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
label length. The selectable range for this option i
s 00 (meaning ignore this length), or 01
to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning
the ENTER/EXIT Programming
Mode bar code.
Set Code 93 Length 2
DEFAULT
Default setting for this feature = 50