Enter/Exit Programming Mode
Product Reference Guide
355
MSI Length 2
If MSI Length Control is set to Fixed-Length decoding, this feature specifies MSI second fixed
length. If MSI Length Control is set to Variable-Length decoding, this feature specifies the
maximum label length.
NOTE
When in Fixed Length mode, if Length 2 is set to the value 00 (zero),
then only Length 1 will apply.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the barcode, Set MSI Length 2 below. You’ll need to cover any unused barcodes on
this and the facing page to ensure that the scanner reads only the barcode you intend to
scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
label length. The selectable range for this option i
s 00 (meaning ignore this length), or 04
to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (00, 04-
16).
4. Complete the programming sequence by scanning
the ENTER/EXIT Programming
Mode bar code.
Set MSI Length 2
DEFAULT
Default setting for this feature = 16