Site Preparation and Installation
48
Magellan™ 9800i Scanner
Figure 34. Using the Lift Handles
8. Lower the unit into the counter opening, ensuring that none of the cables are pinched,
pierced or crimped.
9. View the bubble level (if present
1
) located on the scanner's spider assembly to ensure the
scanner is level. As shown in the insert of
Figure 33, the air bubble should appear fully
within the circle indicated. The air bubble can touch the circle, but must not overlap it.
A
pply shims beneath the scanner flange or adjust the leveling feet to allow level installa-
tion.
10. Reinstall the All Weighs™ Platter and verify that it is flush or just below flush with the
counter
top. This is necessary to provide smooth scanning from either direction. Make
adjustments as needed to align the platter with the counter by moving support rails up or
down, or consider installing screws in positions that will allow their use in adjusting the
unit’s position. Ensure that leveling is maintained if adjustments are made.
NOTE
Failure to install a scanning-scale in a stable and level position will inhibit weigh-
ing, calibration and zeroing operations. The platter MUST make unobstructed
c
ontact with all of its supports for proper weighing operation.
11. Once installation is complete, proceed with the Operational Verification procedures that
follow.
1. The bubble level is present only on certain models.