Calibration Procedures
80
Magellan™ 9800i Scanner
Calibration Verification (Pounds)
Once you have completed the calibration sequence, you may be required to perform these
step-by-step verification procedures. These procedures follow the National Institute of
Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be
required by state or local law to have these procedures performed by a certified technician
or verified by a proper official.
These calibration verification procedures cover five (5)
different tests:
Increasing-Load Test
Shift Test
Blanking Test
Decreasing-Load Test
Return to Zero Test
NOTE
If the scale fails any of the following tests, go to
Section 4, Problem Isolation
, of this manual and
follow the troubleshooting proc
edures for SCALE FAILURE.
Increasing-Load Test (Phase 1)
This test checks Scale operation with two, four and six pound weights.
SINGLE INTERVAL DUAL INTERVAL
This test checks Scale operation with five, ten and
fifteen pound weights.
This test checks Scale operation with two, four and
six pound weights.
1. Check that the display reads 0.00 lb. when at
rest with nothing on the weighing surface. (The
Zero Status LED is steadily lit).
1. Check that the display reads 0.00 lb. when at
rest with nothing on the weighing surface. (The
Zero Status LED is on steady).
2. Place a five-pound weight on the center of the
weighing surface and check that the display
reads 5.00 lb.
2. Place a two-pound weight on the center of the
weighing surface. Verify that the Remote
Display reads 2.00 lb.
3. Place an additional five pounds on the center of
the weighing surface and check that the display
reads between 9.99 and 10.01 lb.
3. Place an additional two pounds (four pounds
total) on the center of the weighing surface. Verify
that the Remote Display reads between 3.995 and
4.005 lb.
4. Place an additional five pounds on the center of
the weighing surface and check that the display
reads between 14.99 and 15.01. Remove the
weights and verify that the display reads 0.00.
4. Place an additional two pounds (six pounds total)
on the center of the weighing surface. Verify that
the Remote Display reads between 5.995 and
6.005. Remove the weights and verify that the
display reads 0.00.
5. You have completed the Increasing-Load Test
(Phase 1).
5. You have completed the Increasing-Load Test
(Phase 1).