MATRIX 400™ REFERENCE MANUAL
4
1
19-pin Connector Pinout for Matrix 400™
The table below gives the pinout of the 19-pin M16 male connector for connection to the
power supply and input/output signals. Use this pinout when the Matrix 400™ reader is
connected by means of the 19-pin connector:
Figure 3 - 19-pin M16 Male Connector
19-pin M16 male connector pinout
Pin Name Function
A Vdc Power supply input voltage +
L GND Power supply input voltage -
K CHASSIS
Cable shield internally connected by capacitor to the
chassis
B I1A External Trigger A (polarity insensitive)
C I1B External Trigger B (polarity insensitive)
D I2A Input 2 A (polarity insensitive)
E I2B Input 2 B (polarity insensitive)
H O1+ Output 1 +
F O1- Output 1 -
G O2+ Output 2 +
I O2- Output 2 -
S RX Auxiliary RS232 RX
O TX Auxiliary RS232 TX
R ID+ ID-NET™ network +
P ID- ID-NET™ network -
Pin Name RS232
RS485
Full-Duplex
RS485
Half-Duplex
M TX TX+ RTX+
U RX *RX+
N RTS TX- RTX-
T
MAIN
INTERFACE
(SW
SELECTABLE)
CTS *RX-
* Do not leave floating, see par. 5.4.2 for connection details.