Rhino II Configuration
User’s Manual 31
Definition of Keyboard-Layouts
The definition of the keyboard layout is done in single lines. For each
line 3-Cfg Keys are possible, according to the status of the special
keys. Max. 20 key lines can be defined per keyboard.
The overall size of the keyboard is automatically calculated based on
the contained buttons.
For XX any number from 01-20 can be specified.
The Syntax is always the same, e.g.:
LXX_Norm=Key1¦Key2¦Key3¦...¦
It is important that even the last keymust always must be
terminated with the vertical bar character “¦“.
The number of keys within a row is not explicity limited, but no more
than 300 keys per keyboard can be defined. Overlapping keys will
not be checked, the definition must be correct at any time.
CloseToggle
0=Off (Default), 1=On, an open keyboard with this mode,
by a repeated call (e.g. carry out by a key or a HW-Key)
can be closed again.
CloseOnTimer
0=Off, Value >= 1000 specifies a timeout value in
milliseconds for this keyboard. If the timer runs out, the
keyboard will be automatically closed. A keystroke on
the keyboard will start the timer each time again.
Keyname Parameter – Info
LXX_Norm Definition of the Key row XX for the normal key status.
LXX_Shift Definition of the Key row XX for the status at pressed Shift-Key.
LXX_AltGr Definition of the Key row XX for the status at pressed AltGr-Key.
Keyname Parameter – Info