GENERAL INFORMATION
6 SG4 EXTENDED
Minimum installation distance
The safety device must be positioned at a specific safety distance (Figure 3).
This distance must ensure that the dangerous area cannot be reached before the dan-
gerous motion of the machine has been stopped by the Safety Control System.
The safety distance depends on 4 factors,
according to the EN ISO 13855 Standard:
Response time of the ESPE (the time betw
een the effective beam interruption and
the opening of the OSSD contacts)
Machine stopping time including Safety Control System computing and actuating
time if
present.
•ESPE resolution
Approaching speed of the object to be detected
Figure 3 - Installation distance (vertical positioning)
The following formula is used for the calculation of the safety distance:
S = K (t1 + t2) + C
where:
S = Minimum safety distance in mm
K = Speed of the object, limb or body approaching the dangerous area in mm/s
t1 = Response time of the ESPE in seconds (see "
Technical Data" on page 83)
t2 = Machine stopping time in seconds (including the Safety Control System)
C = Additional distance based on the possibility t
o insert the body or one of the
body parts inside the dangerous area before the protective device trips.
C=8 (R - 14) for devices with resolution 40
mm
C=850 mm for devices with resolution > 40 mm
R = Resolution of the system
NOTE
K value is:
2000 mm/s if the calculated value of S is 500 mm
1600 mm/s if the calculated value of S is > 500 mm