INSTALLATION
18 SG4 EXTENDED
Controls after first installation
The control operations to carry-out after the first installation and before machine start-
up are listed hereinafter. The controls must be carried-out by qualified personnel, either
directly or under the strict supervision of the person in charge of machinery Safety.
Check that:
The ESPE remains in Safe State intercepting the beams along the detection zone
using the specific t
est piece (TC-14, TP-30), following the scheme shown in Figure
12.
Figure 12 - Path of the test piece
ESPE has to be correctly aligned: press slightly on the product side in both direc-
tions, the red LED must not turn on.
The activation on the TEST function (on TX side) causes the opening of the OSSD
outp
uts (red LED, OSSD on RX side, ON and controlled machine stop).
The response time at machine STOP, including the ESPE and machine response
times, m
ust be included in the limits defined in the calculation of the safety dis-
tance (refer to "
Minimum installation distance" on page 6).
The safety distance between the dangerous
parts and ESPE must comply with the
requirements indicated in "
Minimum installation distance" on page 6.
A person must not access or remain betw
een ESPE and the dangerous parts of the
machine.
Access to the dangerous areas of the machine must not be possible from any
u
nprotected area.
ESPE must not be disturbed by external light sources, ensure that it remains in
N
ormal Operation for at least 10-15 minutes, and placing the specific test piece in
the protected area, in the Safe State for the same period.
Verify the correspondence of all the accessory functions, activating them in the
dif
ferent operating conditions.