FUNCTIONS
54 SG4 EXTENDED
In this case there's a warning that alerts the user that this timeout is not EN 61496-1:
2013 compliant.
Figure 27 - BCM Configuration: Muting timeout
Figure 28 - ACM Configuration: Muting timeout
Muting filter
This function avoids undesired activations of the Muting.
The Muting filter is a filter on Muting inputs; low-high or high-low transitions of MUT-
ING signals are considered valid only if maint
ained for a time (Tf) greater than 100ms.
If this function is disabled, the logical level of the Muting sensors corresponds to the
wi
re level.
Figure 29 - ACM Configuration: Muting Filter
NOTE
Infinite is not EN 61496-1: 2013 compliant thus the user is warned about
it.
Figure 30 - Muting filter disabled Figure 31 - Muting filter enabled