MUTING
INSTRUCTION MANUAL 55
For SG4-N models Muting Filter can be set in BCM mode as follows:
Muting Filter 8
ON
OFF
Partial Muting
It's possible to configure the type of Muting: total or partial.
Partial Muting can be useful in those applications in which the user wants to limit the
Muting function
effects to selected zones only.
In ACM Configuration the user can select a maximum of 5 Muting zones, each defined
with
the following parameters:
• Po
sition: first beam of Muting zone (starting from user display cap)
• Dimen
sion: number of beams of Muting zone
ACM Configuration: Partial Muting Selection
Check “Partial Muting” to enable the function.
Click the “+” button to add a new Muting zone, and the “x” button to remove a selected
on
e.
Choose correct parameters for selected zone. Both Dimension and Position are set in
beams unit, equivalent measures in mm are exposed by GUI.