Data/Link Cable-Check™
#70025
page 1 of 2
Sample Test Results:
RJ45 in Lights Cable Fault
1 2 3 4 5 6 7 8 None, Cable wired correctly
2 1 3 4 5 6 7 8 Conductors 1 & 2 Reversed
1 2 & 3 2 & 3 4 5 6 7 8 Conductors 2 & 3 are Shorted
1 2 3 - 5 6 7 8 Conductor 4 is Open
1 2 4 3 6 5 7 8 Pair 3/6 is Transposed with Pair 4/5
1 2 3 7 5 6 4 8 Conductors 4 & 7 are switched
1 2 3 4 5 6 7 - Conductor 8 is Open
Sample Test Results:
Remote Lights Cable Fault
1 2 3 4 5 6 7 8 None, cable wired correctly
2 1 3 4 5 6 7 8 Conductors 1 & 2 reversed
1 2 & 3 2 & 3 4 5 6 7 8 Conductors 2 & 3 are shorted
1 2 3 - 5 6 7 8 Conductor 4 is open
1 2 4 3 6 5 7 8 Pair 3/6 is transposed with Pair 4/5
1 2 3 7 5 6 4 8 Conductors 4 & 7 are switched
1 2 3 4 5 6 7 - Conductor 8 is open
Good Connection
Pin 4-to-Pin 4
Main Unit Main Unit
In Out
Cross Connection
Pin 6-to-Pin 4
Main Unit Main Unit
In Out
Open Connection
Pin 6
Main Unit Main Unit
In Out
Patch Cable Testing
Good Connection
Pin 4-to-Pin 4
Main Unit
Out Remote
Cross Connection
Pin 4-to-Pin 6
Main Unit
Out Remote
Open Connection
Pin 4
Main Unit
Out Remote
Installed Cable Testing