26
F07.16
Inverter
Power
Consumption
(low byte)
Function
Code
Name
Description
Modi-
ability
-
0.0~
999.9
Unit: kWh
Setting
Range
Default
Value
F07.18
Inverter Rated
Power
Determin
ed by
model
0.4~
3000.0
Unit: kW
F07.19
Inverter Rated
Voltage
Determin
ed by
model
50~1200
Unit: V
F07.20
Inverter Rated
Current
Determin
ed by
model
0.1~
6000.0
Unit: A
F07.27
Current Fault
Type
0: No fault
1: IGBT phase U fault (OUt1)
2: IGBT phase V fault (OUt2)
3: IGBT phase W fault (OUt3)
4: Overcurrent when accelerating (OC1)
5: Overcurrent when decelerating (OC2)
6: Overcurrent when operating in constant
speed (OC3)
7: Overvoltage when accelerating (OU1)
8: Overvoltage when decelerating (OU2)
9: Overvoltage when operating in constant
speed (OU3)
10: DC bus undervoltage (UV)
11: Pump overload (OL1)
12: Inverter overload (OL2)
13: Input phase loss (SPI)
14: Output phase loss (SPO)
15: Rectifier module overheat (OH1)
16: IGBT overheat (OH2)
17: Reserved
18: 485 communication fault (CE)
19: Current detection circuit fault (ItE)
20: Reserved
21: EEFROM r/w fault (EEP)
22: Reserved
23: Breaking unit fault (bC)
24: Operating time over (END)
25: Program defined overload alert (Ol3)
26~31: Reserved
32: Grounding short circuit fault 1 (EtH1)
33: Grounding short circuit fault 2 (EtH2)
34~36: Reserved
Alert:
AL-LU: Low sunlight alert
AL-tF: Tank full alert
AL-SL: Source low alert
AL-LL: Load low alert
- -
F07.28
Latest Fault
Type
- -
F07.29
Penultimate
Time Fault
Type
- -
F07.30
Antepenulti
mate Time
Fault Type
- -
F07.31
Fourth Time
from the End
Fault Type
- -
- -
F07.32
Fifth Time
from the End
Fault Type